The WS-UMB family is a range of affordable smart combinations of weather sensors for the acquisition of a variety of meteorological variables, as used for example for environmental data logging in road traffic management systems.
Overview of models : |
![]() |
Parameters :
Model | Wind | Temp - Hum | Barom. pressure | Precip. type |
Precip. quantity |
Global rad. | Lightning | Compass |
WS100-UMB | x | x | x | x | ||||
WS200-UMB | x | x | ||||||
WS300-UMB | x | x | ||||||
WS301-UMB | x | x | x | |||||
WS302-UMB | x | x | x | |||||
WS310-UMB | x | x | x | |||||
WS400-UMB | x | x | x | x | ||||
WS401-UMB | x | x | x | |||||
WS500-UMB | x | x | x | x | ||||
WS501-UMB | x | x | x | x | x | |||
WS502-UMB | x | x | x | x | x | |||
WS510-UMB | x | x | x | x | x | |||
WS600-UMB | x | x | x | x | x | x | ||
WS601-UMB | x | x | x | x | x | |||
WS700-UMB | x | x | x | x | x | x | x | |
WS800-UMB | x | x | x | x | x | x | x | x |
Included in all models :
- Built-in data pre-processing
- Universal interfaces
- Selectable RS485 output protocols (UMB-Binary, UMB-ASCII, Modbus-RTU, Modbus-ASCII, SDI-12)
- Built-in heater (except Mod. WS30x and WS401)
- Mounting on tube Ø 60 - 76 mm
- Delivered with pluggable 10 m cable (other lengths on demand)
Characteristics :
Wind speed : Measuring range : 0...75 m/s (WS601-USB: 0...30 m/s) Resolution : 0,1 m/s Accuracy : ± 0,3 m/s or ± 3% (0...35 m/s) / ± 5% (>35 m/s) |
Wind direction : Measuring range : 0...359,9 degrees Resolution : 0,1 degree Accuracy : < 3 degrees (> 1m/s) |
Air temperature : Measuring range : -50...+60°C Resolution : 0,1°C Accuracy : ± 0,2°C (-20...+50°C) |
||
Relative humidity : Measuring range : 0...100% Resolution : 0,1% Accuracy : ± 2% |
Dew point (computed) : Measuring range : -50°C...+60°C Resolution : 0,1°C Accuracy : ± 0,7°C |
Barometric pressure : Measuring range : 300...1200 hPa Resolution : 0,1 hPa Accuracy : ± 0,5 hPa (0...40°C) |
||
Precipitation (with radar sensor) : WS100 / 400 / 600 / 700 / 800-UMB Measuring range : 0,3...5 mm Resolution : 0,01 mm Repeatability : Typically > 90 % |
Precipitation (with rain gauge) : WS401 / 601-UMB Resolution : 0,2 mm or 0,5 mm (with reduction ring) Accuracy : 2% |
Lightning : Coverage area : 5 – 10 km Sum : 1 – 10 minutes Sampling rate : 1 minute |
||
Global radiation (A) (with class A pyranometer) : Measuring range : 0...4000 W/m² Resolution : 1 W/m² Accuracy : ± 2% |
Global radiation (B) (with class B pyranometer) : Measuring range : 0...2000 W/m² Resolution : 1 W/m² Accuracy : ± 5% |
Global radiation (C) (with class C pyranometer) : Measuring range : 0...2000 W/m² Resolution : 1 W/m² Accuracy : ± 10% |
||
RS485 interface : Protocol : UMB-Binary, UMB-ASCII, Modbus-RTU, Modbus-ASCII, SDI-12 Mode : Half duplex Baud rates : 1200...57600 bd |
Power : Operating Voltage : 12 – 24 VDC Consumption : 16…160 mA |
Heater : Voltage : 24 VDC Power : 20 or 40 W |
||
Housing : |